134 research outputs found

    Inhibition of Toll-Like Receptor 2-Mediated Interleukin-8 Production in Cystic Fibrosis Airway Epithelial Cells via the α7-Nicotinic Acetylcholine Receptor

    Get PDF
    Cystic Fibrosis (CF) is an inherited disorder characterised by chronic inflammation of the airways. The lung manifestations of CF include colonization with Pseudomonas aeruginosa and Staphylococcus aureus leading to neutrophil-dominated airway inflammation and tissue damage. Inflammation in the CF lung is initiated by microbial components which activate the innate immune response via Toll-like receptors (TLRs), increasing airway epithelial cell production of proinflammatory mediators such as the neutrophil chemokine interleukin-8 (IL-8). Thus modulation of TLR function represents a therapeutic approach for CF. Nicotine is a naturally occurring plant alkaloid. Although it is negatively associated with cigarette smoking and cardiovascular damage, nicotine also has anti-inflammatory properties. Here we investigate the inhibitory capacity of nicotine against TLR2- and TLR4-induced IL-8 production by CFTE29o- airway epithelial cells, determine the role of α7-nAChR (nicotinic acetylcholine receptor) in these events, and provide data to support the potential use of safe nicotine analogues as anti-inflammatories for CF

    A combined Fourier transform infrared and Cr K-edge X-ray absorption near-edge structure spectroscopy study of the substitution and diffusion of H in Cr-doped forsterite

    Get PDF
    International audienceSingle crystals of synthetic Cr-doped forsterite (Cr:Mg2SiO4) containing both Cr3+ and Cr4+ were partially hydroxylated in piston-cylinder apparatuses at 750-1300 degrees C and pressures from 0.5 to 2.5 GPa, with P(H2O) approximate to P-total. The oxygen fugacity (fO(2)) was buffered by graphite-water, Ni-NiO, Re-ReO2, Fe2O3-Fe3O4 or Ag-Ag2O, and the silica activity (a SiO2) was buffered by powdered forsterite plus either enstatite (Mg2Si2O6), periclase (MgO) or zircon-baddeleyite (ZrSiO4-ZrO2). Profiles of OH content versus distance from the crystal edge were determined using Fourier transform infrared (FTIR) spectroscopy, and profiles of the oxidation state and coordination geometry of Cr were obtained, at the same positions, using K-edge X-ray absorption near-edge structure (XANES) spectroscopy. The techniques are complementary - FTIR spectroscopy images the concentration and nature of O-H bonds, where Cr K-edge XANES spectroscopy shows the effect of the added H on the speciation of Cr already present in the lattice. Profiles of defect-specific absorbance derived from FTIR spectra were fitted to solutions of Fick's second law to derive diffusion coefficients, which yield the Arrhenius relationship for H diffusion in forsterite: log(10)(D) over tilde ([001]) = -2.5 +/- 0.6 + -(224 +/- 12 + 4.0 +/- 2.0 P)/2.303 RT , where (D) over tilde is the measured diffusion coefficient in m(2) s(-1), valid for diffusion parallel to [001] and calibrated between 1000 and 750 degrees C, P and T are in GPa and K, and R is 0.008314 kJK(-1) mol(-1). Diffusivity parallel to [100] is around 1 order of magnitude lower. This is consistent with previous determinations of H diffusion associated with M-site vacancies. The FTIR spectra represent a variety of Cr-bearing hydrous defects, along with defects associated with the pure Mg-Si-O-H system. It is proposed that all of the defects can form by interaction between the dry lattice, including Cr3+ and Cr4+, and fully hydroxylated M-site vacancies. The initial diffusive wave of hydroxylation is associated with neither reduction nor oxidation of Cr but with Cr4+ changing from tetrahedral to octahedral coordination. Superimposed on the H diffusion and concomitant change in Cr4+ site occupancy, but at a slower rate, producing shorter profiles, is reduction of Cr4+ to Cr3+ and potentially of Cr4+ and Cr3+ to Cr2+. In addition, by comparing FTIR data to trace element contents measured by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), constraints can be placed on absorption coefficients used for converting absorbance to H2O contents - our data support either wavenumber- or defect-dependent values of absorption coefficients. We estimate absorption coefficients of between 60 200 and 68 200 L mol(-1) cm(-1) for OH- associated with octahedral Cr3+ and an M-site vacancy and 18 700 to 24 900 L mol(-1) cm(-1) for two OH- associated with octahedrally coordinated Cr4+ and a Si vacancy (i.e. a clinohumite-type point defect)

    On the context-dependent scaling of consumer feeding rates

    Get PDF
    The stability of consumer-resource systems can depend on the form of feeding interactions (i.e. functional responses). Size-based models predict interactions - and thus stability - based on consumer-resource size ratios. However, little is known about how interaction contexts (e.g. simple or complex habitats) might alter scaling relationships. Addressing this, we experimentally measured interactions between a large size range of aquatic predators (4-6400 mg over 1347 feeding trials) and an invasive prey that transitions among habitats: from the water column (3D interactions) to simple and complex benthic substrates (2D interactions). Simple and complex substrates mediated successive reductions in capture rates - particularly around the unimodal optimum - and promoted prey population stability in model simulations. Many real consumer-resource systems transition between 2D and 3D interactions, and along complexity gradients. Thus, Context-Dependent Scaling (CDS) of feeding interactions could represent an unrecognised aspect of food webs, and quantifying the extent of CDS might enhance predictive ecology. © 2016 John Wiley & Sons Ltd/CNRS

    Improved Performance of Near infrared Excitation Raman Spectroscopy Using Reflective Thin-film Gold on Glass Substrates for Cytology Samples

    Get PDF
    Confocal near-infrared Raman spectroscopy has been shown to have applications in the area of clinical biology. A source wavelength in the near infrared is preferred over visible wavelengths for inspecting biological samples due to superior wave number resolution and reduced photo damage. However, these excitation sources have a number of drawbacks when compared to lasers in the visible wavelength region, including the requirement to use expensive highly pure crystal substrates such as Raman grade calcium fluoride as well as long acquisition times due to the lower Raman scattering efficiency. This paper investigates the use of a reflective substrate comprising a low cost 100 nm thin-film gold on glass substrate, as an alternative. Similar to recent work that used stainless steel substrates, it is demonstrated that the thin-film gold coated substrates, which are relatively inexpensive, produce cell spectra with 1.65 times the signal to noise ratio when compared with spectra obtained from calcium fluoride under identical conditions, with no apparent background signal in the fingerprint region. Two prostate cell lines are examined having been deposited on glass, calcium fluoride, and thin-film gold on glass substrates using the Thin Prep standard. Background spectra from, and cell adhesion on, these three substrates are compared. A comparison of the intensities and signal to noise ratios of the resulting spectra, and their viability for classification using principle components analysis is performed, which further demonstrates the benefit of reflective substrates

    Cellular discrimination using in vitro Raman micro spectroscopy: the role of the nucleolus.

    Get PDF
    International audienceRaman micro spectroscopy has attracted considerable attention over the last few years to explore its possible clinical applications as a non-invasive powerful label-free in vitro screening tool in cancer diagnosis and monitoring, subcellular analysis of biochemical processes, drug uptake, mode of action and mechanisms of interaction as well as toxicity of, for example, chemotherapeutic agents. However, in order to evaluate accurately the potential of Raman micro spectroscopy for such applications it is essential to optimise measurement and data processing protocols associated with subcellular analysis. To this end, in vitro differentiation of cell lines is a basic proof of concept for the potential of the technique, and although many studies have indicated successful differentiation based on Raman micro spectroscopy, it is important, as the measurement and processing techniques are improved, to establish the biochemical and subcellular basis of that discrimination. In this study, Raman micro spectroscopy is used to compare and differentiate normal and cancer cells from human lung origin, A549 adenocarcinoma cell line, Calu-1 epidermoid non-small-cell and BEAS-2B normal immortalized bronchial epithelium cell line. Spectra were taken from the three subcellular compartments, cytoplasm, nucleus and nucleolus and Principal Components Analysis was used to compare the spectral profiles between the cell lines and, coupled to Linear Discriminant Analysis, to explore the optimum sensitivity and specificity of discrimination. To support the analysis, Raman micro spectroscopy was coupled with Flow Cytometry, Confocal Laser Scanning Microscopy and Atomic Force Microscopy. While all subcellular regions can be employed to differentiate the normal and cancer cell lines, optimum discrimination sensitivity and specificity is achieved using the spectra from the nucleolar region alone. Notably, only the nucleolar spectral profiles differentiate the two cancer cell lines. The results point to the importance of the nucleolar regions in diagnostic applications of Raman microscopy as well as further applications in subcellular analysis of cytological processes

    A touchdown nucleic acid amplification protocol as an alternative to culture backup for immunofluorescence in the routine diagnosis of acute viral respiratory tract infections

    Get PDF
    BACKGROUND: Immunofluorescence and virus culture are the main methods used to diagnose acute respiratory virus infections. Diagnosing these infections using nucleic acid amplification presents technical challenges, one of which is facilitating the different optimal annealing temperatures needed for each virus. To overcome this problem we developed a diagnostic molecular strip which combined a generic nested touchdown protocol with in-house primer master-mixes that could recognise 12 common respiratory viruses. RESULTS: Over an 18 month period a total of 222 specimens were tested by both immunofluorescence and the molecular strip. The specimens came from 103 males (median age 3.5 y), 80 females (median age 9 y) and 5 quality assurance scheme specimens. Viruses were recovered from a number of specimen types including broncho-alveolar lavage, nasopharyngeal secretions, sputa, post-mortem lung tissue and combined throat and nasal swabs. Viral detection by IF was poor in sputa and respiratory swabs. A total of 99 viruses were detected in the study from 79 patients and 4 quality control specimens: 31 by immunofluorescence and 99 using the molecular strip. The strip consistently out-performed immunofluorescence with no loss of diagnostic specificity. CONCLUSIONS: The touchdown protocol with pre-dispensed primer master-mixes was suitable for replacing virus culture for the diagnosis of respiratory viruses which were negative by immunofluorescence. Results by immunofluorescence were available after an average of 4–12 hours while molecular strip results were available within 24 hours, considerably faster than viral culture. The combined strip and touchdown protocol proved to be a convenient and reliable method of testing for multiple viruses in a routine setting

    Improved performance of near infrared excitation Raman spectroscopy using reflective thin-film gold on glass substrates for cytology samples

    Get PDF
    Confocal near-infrared Raman spectroscopy has been shown to have applications in the area of clinical biology. A source wavelength in the near infrared is preferred over visible wavelengths for inspecting biological samples due to superior wavenumber resolution and reduced photodamage. However, these excitation sources have a number of drawbacks when compared to lasers in the visible wavelength region, including the requirement to use expensive highly pure crystal substrates such as Raman grade calcium fluoride as well as long acquisition times due to the lower Raman scattering efficiency. This paper investigates the use of a reflective substrate comprising a low cost 100 nm thin-film gold on glass substrate, as an alternative. Similar to recent work that used stainless steel substrates, it is demonstrated that the thin-film gold coated substrates, which are relatively inexpensive, produce cell spectra with 1.65 times the signal to noise ratio when compared with spectra obtained from calcium fluoride under identical conditions, with no apparent background signal in the fingerprint region. Two prostate cell lines are examined having been deposited on glass, calcium fluoride, and thin-film gold on glass substrates using the ThinPrep standard. Background spectra from, and cell adhesion on, these three substrates are compared. A comparison of the intensities and signal to noise ratios of the resulting spectra, and their viability for classification using principle components analysis is performed, which further demonstrates the benefit of reflective substrates

    Clinical utility of a nested nucleic acid amplification format in comparison to viral culture for the diagnosis of mucosal herpes simplex infection in a genitourinary medicine setting

    Get PDF
    BACKGROUND: Nested nucleic acid amplification tests are often thought too sensitive or prone to generatingfalse positive results for routine use. The current study investigated the specificity and clinicalutility of a routine multiplex nested assay for mucosal herpetic infections. METHODS: Ninety patients, categorised into those clinically diagnosed to (a) have and (b) not haveherpetic infection, were enrolled. Swabs from oral and ano-genital sites were assayed by thenested assay and culture and the results assessed against clinical evaluation for diagnosingherpetic infections; cell content was also recorded. RESULTS: Twenty-six and 64 patients were thought to (a) have and (b) not have mucosal herpeticinfection. Taking the clinical evaluation as indicating the presence of herpetic infection, thenested polymerase chain reaction and culture had respective sensitivities of 19/26 (73%) and12/26 (46%) (Χ(2) p = 0.02). There was no significant difference in specificities between nPCR62/64 (97%) and culture 63/64 (98%) (Χ(2) p = 1.0). Cell content was important for viraldetection by nPCR (Χ(2) p = 0.07) but not culture. Nesting was found necessary for sensitivity anddid not reduce specificity. Assay under-performance appeared related to sub-optimal cellcontent (20%) but may have reflected clinical over-diagnosis. The results suggest the need forvalidating specimen cell quality. CONCLUSIONS: This study questions the value of routine laboratory confirmation of mucosal herpetic infection. The adoption of a more discriminatory usage of laboratory diagnostic facilities for genital herpetic infection, taking account of cell content, and restricting it to those cases where it actually affects patient management, may be warranted
    corecore